Apparel Solutions

  • Phone: 780.434.6100

Ultrasoft 7oz Modified “X” FR Coverall

40MX70US

GARMENT CONSTRUCTION

  • Protective stand-up collar with hook & loop closure, lays flat when worn open
  • YKK Two-way heavy duty #5 brass zipper on Nomex® tape
  • Storm guard over zipper with snap closures
  • Action back for mobility
  • Side elasticized waist
  • Gusset crotch for added mobility and strength
  • Separate arm cuffs with 2 position snap closures
  • Pocket flaps w/ snap closure. Pencil pocket left chest
  • Nomex® mesh pocket left chest
  • Mic loops, adjustable hook & loop leg tabs
  • Reflective tape double stitched

 

SIZING

  • Chest size 36 through 64, Short, Regular & Tall
  • Sizing Chart

STANDARDS MET

  • CAN/CGSB-155.20-2000 (Workwear for Protection Against Hydrocarbon Flash Fire)
  • ATPV 8.7 cal/cm2 Arc Rating
  • PPE Cat 2: CSA Z462 & NFPA 70E (Electrical Arc Flash Apparel Standards)
  • CSA Z96-09 Class 1 (Fluorescent Yellow) Level 2 (High Visibility)

REFLECTIVE TRIM

  • 2″ yellow/silver/yellow–– Industrial wash

FABRIC & COLORS

  • 7 oz UltraSoft® twill weave
  • Fiber content: 88% FR Cotton/12% High Tenacity FR Nylon
  • ASTM F 1930 fabric test (NFPA 2112) 17% 2nd & 3rd degree
  • Garment fabric meets CSA Z96-09 bright orange background material requirements.
  • Stocked in Royal, Navy

Purchase

Nomex IIIA Lined Mid-length Jacket

54DX60NX

GARMENT CONSTRUCTION

  • Protective stand-up collar with snap closure
  • Exterior heavy duty #10 and interior #5 brass zipper on Nomex® tape
  • Storm guard over zipper with snap closures
  • Partially elasticized cuff w/ adjustable hook & loop tab
  • Drop back for extra warmth & protection
  • Reflective tape double stitched
  • 3 in 1 capability- liners sold separately

SIZING

  • Chest size Small through 4XL, Short, Regular & Tall
  • Sizing Chart

STANDARDS MET

  • CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
  • ATPV 14.5 cal/cm2 (TSAR- Total System Arc Rating)
  • PPE cat 2: CSA Z462 & NFPA 70E (Electrical Arc Flash Apparel Standards)

REFLECTIVE TRIM

  • 2″ Yellow/Silver/Yellow –– Industrial wash

COMPONENTS

Outer Shell

  • Inherently flame resistant 6.0 oz Nomex IIIA® plain weave

Wind/Vapour Barrier

  • 3.25 oz separate, one way breathable for wind & moisture resistance

Inner Liner

  • 3.25 oz Nomex IIIA® inner liner

COLORS

  • Stocked in royal

Purchase

UltraSoft Insulated Bomber

53DX90US

GARMENT CONSTRUCTION

  • Protective insulated stand-up collar
  • Two-way heavy duty #10 brass zipper on Nomex® tape
  • Storm guard over zipper with snap closures
  • Partially elasticized cuff w/ adjustable hook & loop tab
  • Fully elasticized separate waistband
  • Reflective tape double stitched

SIZING

  • Chest size Small through 4XL, Short, Regular & Tall
  • Sizing Chart

STANDARDS MET

  • CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
  • PPE cat 2: CSA Z462 & NFPA 70E (Electrical Workplace Standards)

 REFLECTIVE TRIM

  • 2″ Yellow/Silver/Yellow–– Industrial wash

COMPONENTS & COLORS

Outer Shell

  • 9 oz UltraSoft® twill weave
  • the High Performance and comfortable FR cotton
  • Stocked in Royal

Wind/Vapour Barrier

  • 3.25 oz separate, one way breathable for wind & moisture resistance

Insulation

  • Quilted flame resistant 14 oz Modacrylic

Purchase

UltraSoft 6oz Henley Shirt

74HS65UKNV

GARMENT CONSTRUCTION

  • Rib knit collar
  • 3 button placket
  • Relaxed fit
  • Rib Knit cuffs
  • Split-side hem

 SIZING

  • Regular SR-5XLR

STANDARDS MET

  • CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
  • ATPV 10.9 cal/cm2, ASTM F 1506 (Electric Arc Rating)
  • PPE cat 2: CSA Z462 & NFPA 70E (Electrical Workplace Safety Standards)

 REFLECTIVE TRIM

  • Non applicable

 FABRIC & COLORS

  • 6.0 oz UltraSoft®  knit
  • 88% FR Cotton / 12% High tenacity nylon
  • Stocked in Navy

Purchase

Midweight FR L/S T-shirt

74LS64PDNV/74WLS64PDNV

GARMENT CONSTRUCTION

  • Moisture wicking & fast drying
  • Flat-lock seam construction
  • Soft fabric prevents chaffing
  • Base layer under other FR garments
  • 74WLS specifically tailored for a woman’s build

 SIZING

 

STANDARDS MET

  • NFPA-2112 (Flash Fire Workwear)
  • ATPV 9.5 cal/cm2, ASTM F 1506 (Electric Arc Rating)
  • PPE cat 2: CSA Z462 & NFPA 70E (Electrical Workplace Safety Standards)

 REFLECTIVE TRIM

  • Not applicable

 FABRIC & COLORS

  • 6.4oz Polartec® Power Dry® FR
  • 45% Rayon/ 40% Modacrylic/ 15% Para Aramid
  • Stocked in navy

Purchase

Welder Coverall

 

40WD10CT

GARMENT CONSTRUCTION

  • Protective stand-up collar with hook & loop closure, lays flat when worn open
  • Snap front closure with storm guard
  • Action back for mobility
  • Side elasticized waist
  • Reflective trim placed on upper arms
  • Separate arm cuffs with 2 position snap closures

 

SIZING

  • Chest size Small through 6XL, Regular & Tall
  • Sizing Chart

 

FABRIC & COLORS

  • Carinae 100% Fr Treated Cotton
  • 10oz Sateen Weave
  • Teflon® by DuPont® finish – suitable for water, dirt and welders sparks repellency
  • Fabric meets CAN/CGSB 155.20
  • Stocked in Navy

Purchase

Arcflash Coverall

40AF70US

GARMENT CONSTRUCTION

  • Protective stand-up collar with hook & loop closure, lays flat when worn open
  • Heavy duty tear away flame/heat resistant Vislon® zipper on Nomex® tape
  • Storm guard over zipper with snap closures
  • Action back for mobility
  • Adjustable waist w/ hook & loop tabs
  • Gusset crotch for added mobility and strength
  • Separate arm cuffs with 2 position snap closures
  • 20″ Heavy duty flame/heat resistant Vislon® zipper at cuff
  • Reflective tape double stitched

 

SIZING

  • Chest size 36 through 64, Short, Regular & Tall
  • Sizing Chart

STANDARDS MET

  • CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
  • ATPV 8.7 cal/cm2 (Electric Arc Rating)
  • PPE cat 2: CSA Z462 & NFPA 70E (Electrical Workplace Safety Standards)
  • CSA Z96 Class 1 (Fluorescent Yellow) Level 2 (High Visibility)

FABRIC & COLORS

  • 7 oz UltraSoft® twill weave
  • the High Performance and comfortable FR cotton
  • 88% Flame Resistant Cotton/12% High Tenacity FR Nylon
  • ASTM F 1930 fabric test (NFPA 2112) 17.0% 2nd & 3rd degree
  • Garment fabric meets CSA Z96-09 bright orange background material requirements.

Purchase

Power Grid Beanie Toque

 

DFB900DH- Power Grid™ Beanie Toque

FABRIC

  • Polartec® Power Grid™ fleece
  • HRC  2: CSA Z462-08 & NFPA 70E (Workplace Electrical Safety Standards)

GARMENT CONSTRUCTION

  • Flat-lock seams
  • 4-way stretch

SIZING

  • One size

 

 

Purchase

Hi-Vis Midweight FR L/S T-shirt

74EX64PDOR

GARMENT CONSTRUCTION

  • Moisture wicking & fast drying
  • Flat-lock seam construction
  • Soft fabric prevents chaffing
  • Base layer under other FR garments

 SIZING

 

STANDARDS MET

  • NFPA-2112 (Flash Fire Workwear)
  • CSA Z96-09 Class 2- Level 2 (High Visibility)
  • ATPV 9.5 cal/cm2, ASTM F 1506 (Electric Arc Rating)
  • PPE cat 2: CSA Z462 & NFPA 70E (Electrical Workplace Safety Standards)

 REFLECTIVE TRIM

  • 2″ segmented heat-applied silver tape

 FABRIC & COLORS

  • 6.4oz Polartec® Power Dry® FR
  • 45% Rayon/ 40% Modacrylic/ 15% Para Aramid
  • Stocked in orange

Purchase

Modacrylic Fleece Jacket w/ Detachable Hood

68FZ12MC

GARMENT CONSTRUCTION

  • Protective stand-up collar
  • Heavy duty #5 brass zipper on Nomex® tape
  • Rib knit cuffs
  • Rib knit waistband
  • Interior storm flap at zipper
  • Detachable hood w/ snaps

SIZING

STANDARDS MET

  • CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
  • 14 cal/cm2 Ebt Arc  Rating
  • PPE cat 2: CSA Z462 & NFPA 70E (Electrical Workplace Safety Standards)

 REFLECTIVE TRIM

  • Not Applicable

FABRIC & COLORS

  • 12.0 oz modacrylic fleece
  • Fiber content: 46% Modacrylic/38% Cotton/16% Aramid
  • Stocked in Navy

Purchase