Apparel Solutions

Nomex 111A FR Coverall

40DX60NX

GARMENT CONSTRUCTION

  • Protective stand-up collar with hook & loop closure, lays flat when worn open
  • YKK Two-way heavy duty #5 brass zipper on Nomex® tape
  • Storm guard over zipper with snap closures
  • Action back for mobility
  • Side elasticized waist
  • Gusset crotch for added mobility and strength
  • Separate arm cuffs with 2 position snap closures
  • Pencil pocket left sleeve
  • Adjustable hook & loop leg tabs
  • Reflective tape double stitched

 

SIZING

  • Chest size 36 through 64, Short, Regular & Tall
  • Sizing Chart

STANDARDS MET

  • CAN/CGSB-155.20-2000 (Workwear for Protection Against Hydrocarbon Flash Fire)
  • UL certified to NFPA 2112-2012  (Standard on Flame-Resistant Garments for Protection of Industrial Personnel Against Flash Fire)
  • ATPV 5.1 cal/cm2 Arc Rating
  • PPE cat 1: CSA Z462 & NFPA 70E (Electrical Arc Flash Apparel Standards)

 REFLECTIVE TRIM

  • 2″ yellow/silver/yellow–– Industrial wash

FABRIC & COLORS

  • Inherently flame resistant 6 oz Nomex IIIA® plain weave
  • Fiber content: 100% Nomex IIIA®
  • ASTM F 1930 fabric test (NFPA 2112) 20.76% 2nd & 3rd degree
  • Stocked in Royal, Red

Purchase

Nomex IIIA Insulated Coverall

48DX60NX

GARMENT CONSTRUCTION

  • Protective insulated stand-up collar
  • All three zippers are two-way heavy duty #10 brass zipper on Nomex® tape
  • Front center zipper has insulated storm guard over zipper
  • Inset Nomex® knit sleeve cuff for warmth and lower arm protection
  • Full length leg zippers
  • Side elasticated waist
  • Reflective tape double stitched

 

SIZING

  • Chest size Small through 4XL, Short, Regular & Tall
  • Sizing Chart

STANDARDS MET

  • CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
  • PPE cat 2: CSA Z462 & NFPA 70E (Electrical Workplace Standards)

 REFLECTIVE TRIM

  • 2″ Yellow/silver/yellow –– Industrial wash

COMPONENTS & COLORS

Outer Shell

  • Inherently flame resistant 6.0 oz Nomex IIIA® plain weave
  • Stocked in Royal

Wind/Vapour Barrier

  • 3.25 oz separate, one way breathable for wind & moisture resistance

Insulation

  • Quilted flame resistant 14 oz Modacrylic

Purchase

Nomex IIIA Insulated Parka

50DX60NX

GARMENT CONSTRUCTION

  • Protective insulated stand-up collar
  • Two-way heavy duty #10 brass zipper on Nomex® tape
  • Storm guard over zipper with snap closures
  • Inset Nomex® knit sleeve cuff for warmth and lower arm protection
  • Adjustable interior drawstring at waist
  • Quilted handwarmer pockets
  • Reflective tape double stitched

 

SIZING

  • Chest size Small through 4XL, Short, Regular & Tall
  • Sizing Chart

STANDARDS MET

  • CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
  • PPE cat 2: CSA Z462 & NFPA 70E (Electrical Workplace Standards)

 REFLECTIVE TRIM

  • 2″ Yellow/Silver/Yellow –– Industrial wash

COMPONENTS & COLORS

Outer Shell

  • Inherently flame resistant 6.0 oz Nomex IIIA® plain weave
  • Stocked in Royal & Red

Wind/Vapour Barrier

  • 3.25 oz separate, one way breathable for wind & moisture resistance

Insulation

  • Quilted flame resistant 14 oz Modacrylic

Purchase

Nomex IIIA Insulated Bib Pant

62DX60NX

GARMENT CONSTRUCTION

  • Full leg two-way heavy duty #10 brass zipper on Nomex® tape
  • Front two-way heavy duty #10 brass zipper on Nomex® tape
  • Elasticized shoulder straps with non-conductive adjustable hardware
  • Double layer knees
  • Full height bib front
  • Side elasticated waist
  • Reflective tape double stitched

 

SIZING

  • Chest size Small through 4XL, Short, Regular & Tall
  • Sizing Chart

STANDARDS MET

  • CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
  • PPE cat 2: CSA Z462 & NFPA 70E (Electrical Workplace Standards)

 REFLECTIVE TRIM

  • 2″ Yellow/Silver/Yellow–– Industrial wash

COMPONENTS & COLORS

Outer Shell

  • Inherently flame resistant 6.0 oz Nomex IIIA® plain weave
  • Stocked in Royal, Red

Wind/Vapour Barrier

  • 3.25 oz separate, one way breathable for wind & moisture resistance

Insulation

  • Quilted flame resistant 14 oz Modacrylic

Purchase

Nomex IIIA Lined Mountaineer

52DX60NX

*Discontinued- quantities limited

GARMENT CONSTRUCTION

  • Protective stand-up collar with snap closure
  • Exterior heavy duty #10 and interior #5 brass zipper on Nomex® tape
  • Storm guard over zipper with snap closures
  • Adjustable hook & loop tab on cuff for warmth and lower arm protection
  • Adjustable drawstring waist for wind protection
  • Reflective tape double stitched
  • 3 in 1 capability- liners sold separately

SIZING

  • Chest size Small through 4XL, Short, Regular & Tall
  • Sizing Chart

STANDARDS MET

  • CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)

REFLECTIVE TRIM

  • 2″ Yellow/Silver/Yellow –– Industrial wash

COMPONENTS

Outer Shell

  • Inherently flame resistant 6.0 oz Nomex IIIA® plain weave

Wind/Vapour Barrier

  • 3.25 oz separate, one way breathable for wind & moisture resistance

Inner Liner

  • 3.25 oz Nomex IIIA® inner liner

COLORS

  • Stocked in royal

Purchase

Nomex IIIA Lined Bomber

55DX60NX

*Discontinued- quantities limited

GARMENT CONSTRUCTION

  • Protective stand-up collar with snap closure
  • Exterior heavy duty #10 and interior #5 brass zipper on Nomex® tape
  • Storm guard over zipper with snap closures
  • Adjustable hook & loop tab on cuff for warmth and lower arm protection
  • Fully elasticized waistband
  • Reflective tape double stitched
  • 3 in 1 capability- liners sold separately

SIZING

  • Chest size Small through 4XL, Short, Regular & Tall
  • Sizing Chart

STANDARDS MET

  • CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)

 REFLECTIVE TRIM

  • 2″ Yellow/Silver/Yellow –– Industrial wash

COMPONENTS

Outer Shell

  • Inherently flame resistant 6.0 oz Nomex IIIA® plain weave

Wind/Vapour Barrier

  • 3.25 oz separate, one way breathable for wind & moisture resistance

Inner Liner

  • 3.25 oz Nomex IIIA® inner liner

COLORS

  • Stocked in royal

Purchase

Hard Hat Liner

 

OUTER SHELL- 20H4US

  • 9 oz UltraSoft® twill weave
  • 88% Flame Resistant Cotton/12% High Tenacity FR Nylon
  • ASTM F 1930 (NFPA 2112) 9% 2nd & 3rd degree
  • Stocked in Royal, Red, Grey

 GARMENT CONSTRUCTION

  • Quilted flame resistant 14 oz Moda-Quilt® insulation
  • Available in 4 hole configuration
  • Adjustable chin strap with hook & loop closure

SIZING

  • One size

OUTER SHELL-20H4NX & 20H6NX

  • Inherently flame resistant 6 oz Nomex IIIA® plain weave
  • ASTM F 1930 (NFPA 2112) 25.41% 2nd & 3rd degree
  • Stocked in Royal

 GARMENT CONSTRUCTION

  • Quilted flame resistant 14 oz Moda-Quilt® insulation
  • Available in 4 hole or 6 hole configurations
  • Adjustable chin strap with hook & loop closure

SIZING

  • One size

 

 

Purchase

Nomex IIIA Work Shirt

70BF60NX

GARMENT CONSTRUCTION

  • Button down collar
  • Placket front with button closure
  • Pleated back yoke
  • Two patch chest pockets with flap, button closure
  • Pencil slot in left pocket
  • Adjustable button cuffs
  • Hemmed bottom edge

SIZING

STANDARDS MET

  • CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
  • ATPV 5.1 cal/cm2 (Electric Arc Rating)
  • PPE cat 1: CSA Z462 & NFPA 70E (Electrical Workplace Safety Standards)

 

REFLECTIVE TRIM

  • Non applicable

FABRIC & COLORS

  • Inherently flame resistant 6 oz Nomex IIIA® plain weave
  • 100% Nomex IIIA®
  • ASTM F 1930 (NFPA 2112) 20.76% 2nd & 3rd degree
  • Stocked in Royal

Purchase

Nomex IIIA Work Pant

60WP60NX

GARMENT CONSTRUCTION

  • Button front closure
  • #5 zipper set to Nomex® tape
  • 7 belt loops
  • Two front slash pockets
  • Two back welt pockets
  • Unfinished bottom hem
  • Relaxed fit

SIZING

STANDARDS MET

  • CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
  • ATPV 5.1 cal/cm2 (Electric Arc Rating)
  • PPE cat 1: CSA Z462 & NFPA 70E (Electrical Workplace Safety Standards)

 

REFLECTIVE TRIM

  • Non applicable

FABRIC & COLORS

  • Inherently flame resistant 6 oz Nomex IIIA® plain weave
  • 100% Nomex IIIA®
  • ASTM F 1930 fabric test (NFPA 2112) 20.76% 2nd & 3rd degree
  • Stocked in Royal

Purchase

Nomex IIIA Insulated Bomber

53DX60NX

GARMENT CONSTRUCTION

  • Protective insulated stand-up collar
  • Two-way heavy duty #10 brass zipper on Nomex® tape
  • Storm guard over zipper with snap closures
  • Partially elasticized cuff w/ adjustable hook & loop tab
  • Fully elasticized separate waistband
  • Reflective tape double stitched

SIZING

  • Chest size Small through 4XL, Short, Regular & Tall
  • Sizing Chart

STANDARDS MET

  • CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
  • PPE cat 2: CSA Z462 & NFPA 70E (Electrical Workplace Standards)

 REFLECTIVE TRIM

  • 2″ Yellow/Silver/Yellow–– Industrial wash

COMPONENTS & COLORS

Outer Shell

  • Inherently flame resistant 6.0 oz Nomex IIIA® plain weave
  • Stocked in Royal

Wind/Vapour Barrier

  • 3.25 oz separate, one way breathable for wind & moisture resistance

Insulation

  • Quilted flame resistant 14 oz Modacrylic

Purchase

Nomex IIIA Fleece Jacket w/ Tape

56DX13NXBK

GARMENT CONSTRUCTION

  • Protective stand-up collar
  • Heavy duty #5 brass zipper on Nomex® tape
  • Elasticized cuffs
  • Adjustable drawstring closure at waist
  • Interior storm flap at zipper
  • 3 in 1 capability- Outer shell sold separately

SIZING

STANDARDS MET

  • ASTM F 1506 Electric Arc Flash Apparel Standard
  •  24.4 cal/cm2 Ebt Arc Rating
  • PPE cat 2: CSA Z462 & NFPA 70E (Electrical Workplace Safety Standards)

 REFLECTIVE TRIM

  • 2″ Yellow/Silver/Yellow –– Industrial wash

FABRIC & COLORS

  • Inherently flame resistant 13 oz Nomex IIIA® fleece
  • Stocked in black

Purchase

“Hot Head” Hard Hat Liner- Nomex fleece neck guard

GARMENT CONSTRUCTION

  • Quilted flame resistant 14 oz modacrylic insulation
  • Adjustable hook & loop straps to attach in hard hat suspensions
  • Reinforced “cut through” points
  • Hook & loop closure at chin
  • Nomex®  fleece neck guard

OUTER SHELL-21HH90US

  • 9 oz UltraSoft® twill weave
  • 88% Flame Resistant Cotton/12% High Tenacity FR Nylon
  • ASTM F 1930 (NFPA 2112) 9% 2nd & 3rd degree
  • Stocked in Royal, Red, Grey

PPE STANDARDS MET

  • CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
  • 12.4 cal/cm2 ATPV, ASTM F 1506 (Arc Flash Rating)
  • PPE cat 2: CSA Z462 & NFPA 70E (Workplace Electrical Safety Standards)

OUTER SHELL-21HH60NX

  • Inherently flame resistant 6 oz Nomex IIIA® plain weave
  • Fiber content: 100% Nomex IIIA®
  • ASTM F 1930 fabric test (NFPA 2112) 20.76% 2nd & 3rd degree
  • Stocked in Royal

PPE STANDARDS MET

  • CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
  • ATPV 5.1 cal/cm2 Arc Rating
  • PPE cat 1: CSA Z462 & NFPA 70E (Electrical Arc Flash Apparel Standards)

SIZING

  •  One size

Purchase

Nomex IIIA Fleece Jacket

56FL13NXBK

GARMENT CONSTRUCTION

  • Protective stand-up collar
  • Heavy duty #5 brass zipper on Nomex® tape
  • Elasticized cuffs
  • Adjustable drawstring closure at waist
  • Interior storm flap at zipper
  • 3 in 1 capability- Outer shell sold separately

SIZING

STANDARDS MET

  • ASTM F 1506 Electric Arc Flash Apparel Standard
  •  24.4 cal/cm2 Ebt Arc Rating
  • PPE cat 2: CSA Z462 & NFPA 70E (Electrical Workplace Safety Standards)

 REFLECTIVE TRIM

  • Not Applicable

FABRIC & COLORS

  • Inherently flame resistant 13 oz Nomex IIIA® fleece
  • Stocked in black

Purchase

Nomex IIIA Insulated Vest

30DX60NX

GARMENT CONSTRUCTION

  • Protective insulated stand-up collar
  • Two-way heavy duty #10 brass zipper on Nomex® tape
  • Storm guard over zipper with snap closures
  • Nomex® mesh pocket
  • Mic loops
  • Reflective tape double stitched

SIZING

STANDARDS MET

  • CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
  • PPE cat 2: CSA Z462 & NFPA 70E (Electrical Workplace Standards)

 REFLECTIVE TRIM

  • 2″ Yellow/Silver/Yellow –– Industrial wash

COMPONENTS & COLORS

Outer Shell

  • Inherently flame resistant 6.0 oz Nomex IIIA® plain weave
  • Stocked in Royal

Wind/Vapour Barrier

  • 3.25 oz separate, one way breathable for wind & moisture resistance

Insulation

  • Quilted flame resistant 14 oz Modacrylic

Purchase

Nomex 111A Class 1 FR Coverall

40C160NX

GARMENT CONSTRUCTION

  • Protective stand-up collar with hook & loop closure, lays flat when worn open
  • YKK Two-way heavy duty #5 brass zipper on Nomex® tape
  • Storm guard over zipper with snap closures
  • Action back for mobility
  • Side elasticized waist
  • Gusset crotch for added mobility and strength
  • Separate arm cuffs with 2 position snap closures
  • Pocket flaps w/ snap closure. Pencil pocket left chest
  • Reflective tape double stitched

 

SIZING

  • Chest size 36 through 64, Short, Regular & Tall
  • Sizing Chart

STANDARDS MET

  • CAN/CGSB-155.20-2000 (Workwear for Protection Against Hydrocarbon Flash Fire)
  • ATPV 5.1 cal/cm2 Arc Rating
  • PPE Cat 1: CSA Z462 & NFPA 70E (Electrical Arc Flash Apparel Standards)
  • CSA Z96 Class 1 (Fluorescent Yellow) Level 2 (High Visibility)

REFLECTIVE TRIM

  • 2″ yellow/silver/yellow–– Industrial wash

FABRIC

  • Inherently flame resistant 6 oz Nomex IIIA® plain weave
  • Fiber content: 100% Nomex IIIA®
  • ASTM F 1930 fabric test (NFPA 2112) 20.76% 2nd & 3rd degree
  • Garment fabric meets CSA Z96-09 bright orange background material requirements.
  • Available in Orange

Purchase

Nomex IIIA Class 1 Insulated Parka

50C160NX

GARMENT CONSTRUCTION

  • Protective insulated stand-up collar
  • Two-way heavy duty #10 brass zipper on Nomex® tape
  • Storm guard over zipper with snap closures
  • Inset Nomex® knit sleeve cuff for warmth and lower arm protection
  • Adjustable interior drawstring at waist
  • Quilted handwarmer pockets
  • Reflective tape double stitched

 

SIZING

  • Chest size Small through 4XL, Short, Regular & Tall
  • Sizing Chart

STANDARDS MET

  • CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
  • PPE Cat 2: CSA Z462 & NFPA 70E (Electrical Workplace Standards)
  • CSA Z96 Class 1 (Fluorescent Yellow) Level 2 (High Visibility)

 REFLECTIVE TRIM

  • 2″ yellow/silver/yellow–– Industrial wash

COMPONENTS

Outer Shell

  • Inherently flame resistant 6.0 oz Nomex IIIA® plain weave

Wind/Vapour Barrier

  • 3.25 oz separate, one way breathable for wind & moisture resistance

Insulation

  • Quilted flame resistant 14 oz Modacrylic

COLORS

  • Available in Orange

Purchase

Nomex IIIA Class 1 Fleece Jacket

56C113NF

GARMENT CONSTRUCTION

  • Protective stand-up collar
  • Heavy duty #5 Vislon® zipper on Nomex® tape
  • Elasticized cuffs
  • Adjustable drawstring closure at waist
  • Interior storm flap at zipper
  • 3 in 1 capability- 55C1 Outer shell sold separately

SIZING

STANDARDS MET

  • ASTM F 1506 Electric Arc Flash Apparel Standard
  •  24.4 cal/cm2 Ebt Arc Rating
  • PPE cat 2: CSA Z462 & NFPA 70E (Electrical Workplace Safety Standards)
  • CSA Z96 Class 1 (Fluorescent Yellow) Level 2 (High Visibility)

 REFLECTIVE TRIM

  • 2″ yellow/silver/yellow –– Industrial wash

FABRIC & COLORS

  • Inherently flame resistant 13 oz Nomex IIIA® fleece
  • Available in Orange

Purchase

Nomex IIIA Class 1 Lined Bomber

55C160NX

GARMENT CONSTRUCTION

  • Protective stand-up collar with snap closure
  • Exterior heavy duty #10 and interior #5 Vislon® zipper on Nomex® tape
  • Storm guard over zipper with snap closures
  • Adjustable hook & loop tab on cuff for warmth and lower arm protection
  • Fully elasticized waistband
  • Reflective tape double stitched
  • 3 in 1 capability- 56C1 liners sold separately

SIZING

  • Chest size Small through 4XL, Short, Regular & Tall
  • Sizing Chart

STANDARDS MET

  • CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)

 REFLECTIVE TRIM

  • 2″ yellow/silver/yellow –– Industrial wash

COMPONENTS

Outer Shell

  • Inherently flame resistant 6.0 oz Nomex IIIA® plain weave

Wind/Vapour Barrier

  • 3.25 oz separate, one way breathable for wind & moisture resistance

Inner Liner

  • 3.25 oz Nomex IIIA® inner liner

COLORS

  • Available in Orange

Purchase

Nomex IIIA Lined Mid-length Jacket

54DX60NX

GARMENT CONSTRUCTION

  • Protective stand-up collar with snap closure
  • Exterior heavy duty #10 and interior #5 brass zipper on Nomex® tape
  • Storm guard over zipper with snap closures
  • Partially elasticized cuff w/ adjustable hook & loop tab
  • Drop back for extra warmth & protection
  • Reflective tape double stitched
  • 3 in 1 capability- liners sold separately

SIZING

  • Chest size Small through 4XL, Short, Regular & Tall
  • Sizing Chart

STANDARDS MET

  • CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
  • ATPV 14.5 cal/cm2 (TSAR- Total System Arc Rating)
  • PPE cat 2: CSA Z462 & NFPA 70E (Electrical Arc Flash Apparel Standards)

REFLECTIVE TRIM

  • 2″ Yellow/Silver/Yellow –– Industrial wash

COMPONENTS

Outer Shell

  • Inherently flame resistant 6.0 oz Nomex IIIA® plain weave

Wind/Vapour Barrier

  • 3.25 oz separate, one way breathable for wind & moisture resistance

Inner Liner

  • 3.25 oz Nomex IIIA® inner liner

COLORS

  • Stocked in royal

Purchase

Recycled Nomex® FR Coverall

40PR70NX

GARMENT CONSTRUCTION

  • Protective stand-up collar with hook & loop closure, lays flat when worn open
  • YKK Two-way heavy duty #5 brass zipper on Nomex® tape
  • Storm guard over zipper with snap closures
  • Action back for mobility
  • Side elasticized waist
  • Separate arm cuffs with snap closures
  • Double pencil pocket left sleeve
  • Reflective tape double stitched

 

SIZING

STANDARDS MET

  • CAN/CGSB-155.20-2000 (Workwear for Protection Against Hydrocarbon Flash Fire)
  • ATPV 8.2 cal/cm2 Arc Rating
  • PPE cat 2: CSA Z462 & NFPA 70E (Electrical Arc Flash Apparel Standards)

REFLECTIVE TRIM

  • 2″ yellow/silver/yellow–– Industrial wash

FABRIC & COLORS

  • 7 oz GR twill weave
  • Fiber content: 70% aramid/20% modacrylic/8% nylon/2% anti-static
  • ASTM F1930 2nd & 3rd degree burns: fabric test =14.5 % (3 sec)
  • Stocked in Royal

Purchase