Nomex 111A FR Coverall
GARMENT CONSTRUCTION
- Protective stand-up collar with hook & loop closure, lays flat when worn open
- YKK Two-way heavy duty #5 brass zipper on Nomex® tape
- Storm guard over zipper with snap closures
- Action back for mobility
- Side elasticized waist
- Gusset crotch for added mobility and strength
- Separate arm cuffs with 2 position snap closures
- Pencil pocket left chest
- Adjustable hook & loop leg tabs
- Reflective tape double stitched
SIZING
- Chest size 36 through 64, Short, Regular & Tall
- Sizing Chart
STANDARDS MET
- CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
- HRC 1: CSA Z462-08 & NFPA 70E (Electrical Workplace Standards)
- ATPV 5.1 cal/cm2 (Electric Arc Flash Rating)
REFLECTIVE TRIM
- Reflective WorX FR5020 –– Industrial wash
FABRIC
- Inherently flame resistant 6 oz Nomex IIIA® plain weave 100% Nomex IIIA®
- ASTM F 1930 (NFPA 2112) 25.41% 2nd & 3rd degree
Nomex IIIA Insulated Coverall
GARMENT CONSTRUCTION
- Protective insulated stand-up collar
- All three zippers are two-way heavy duty #10 brass zipper on Nomex® tape
- Front center zipper has insulated storm guard over zipper
- Inset Nomex® knit sleeve cuff for warmth and lower arm protection
- Full length leg zippers
- Side elasticated waist
- Reflective tape double stitched
SIZING
- Chest size Small through 4XL, Short, Regular & Tall
- Sizing Chart
STANDARDS MET
- CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
- HRC 1: CSA Z462-08 & NFPA 70E (Electrical Workplace Standards)
REFLECTIVE TRIM
- Reflective WorX FR5020 –– Industrial wash
COMPONENTS
Outer Shell
- Inherently flame resistant 6.0 oz Nomex IIIA® plain weave
Wind/Vapour Barrier
- 3.25 oz separate, one way breathable for wind & moisture resistance
Insulation
- Quilted flame resistant 14 oz Moda-Quilt®
Nomex IIIA Insulated Parka
GARMENT CONSTRUCTION
- Protective insulated stand-up collar
- Two-way heavy duty #10 brass zipper on Nomex® tape
- Storm guard over zipper with snap closures
- Inset Nomex® knit sleeve cuff for warmth and lower arm protection
- Adjustable interior drawstring at waist
- Quilted handwarmer pockets
- Reflective tape double stitched
SIZING
- Chest size Small through 4XL, Short, Regular & Tall
- Sizing Chart
STANDARDS MET
- CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
- HRC 1: CSA Z462-08 & NFPA 70E (Electrical Workplace Standards)
REFLECTIVE TRIM
- Reflective WorX FR5020 –– Industrial wash
COMPONENTS
Outer Shell
- Inherently flame resistant 6.0 oz Nomex IIIA® plain weave
Wind/Vapour Barrier
- 3.25 oz separate, one way breathable for wind & moisture resistance
Insulation
- Quilted flame resistant 14 oz Moda-Quilt®
Nomex IIIA Insulated Bib Pant
GARMENT CONSTRUCTION
- Full leg two-way heavy duty #10 brass zipper on Nomex® tape
- Front two-way heavy duty #10 brass zipper on Nomex® tape
- Elasticized shoulder straps with non-conductive adjustable hardware
- Double layer knees
- Full height bib front
- Side elasticated waist
- Reflective tape double stitched
SIZING
- Chest size Small through 4XL, Short, Regular & Tall
- Sizing Chart
STANDARDS MET
- CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
- HRC 1: CSA Z462-08 & NFPA 70E (Electrical Workplace Standards)
REFLECTIVE TRIM
- Reflective WorX FR5020 –– Industrial wash
COMPONENTS
Outer Shell
- Inherently flame resistant 6.0 oz Nomex IIIA® plain weave
Wind/Vapour Barrier
- 3.25 oz separate, one way breathable for wind & moisture resistance
Insulation
- Quilted flame resistant 14 oz Moda-Quilt®
Nomex IIIA Lined Mountaineer
GARMENT CONSTRUCTION
- Protective stand-up collar with snap closure
- Exterior heavy duty #10 and interior #5 brass zipper on Nomex® tape
- Storm guard over zipper with snap closures
- Adjustable hook & loop tab on cuff for warmth and lower arm protection
- Adjustable drawstring waist for wind protection
- Reflective tape double stitched
- 3 in 1 capability- liners sold separately
SIZING
- Chest size Small through 4XL, Short, Regular & Tall
- Sizing Chart
STANDARDS MET
- CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
REFLECTIVE TRIM
- Reflective WorX FR5020 –– Industrial wash
COMPONENTS
Outer Shell
- Inherently flame resistant 6.0 oz Nomex IIIA® plain weave
Wind/Vapour Barrier
- 3.25 oz separate, one way breathable for wind & moisture resistance
Inner Liner
- 3.25 oz Nomex IIIA® inner liner
Nomex IIIA Lined Bomber
GARMENT CONSTRUCTION
- Protective stand-up collar with snap closure
- Exterior heavy duty #10 and interior #5 brass zipper on Nomex® tape
- Storm guard over zipper with snap closures
- Adjustable hook & loop tab on cuff for warmth and lower arm protection
- Fully elasticized waistband
- Reflective tape double stitched
- 3 in 1 capability- liners sold separately
SIZING
- Chest size Small through 4XL, Short, Regular & Tall
- Sizing Chart
STANDARDS MET
- CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
REFLECTIVE TRIM
- Reflective WorX FR5020 –– Industrial wash
COMPONENTS
Outer Shell
- Inherently flame resistant 6.0 oz Nomex IIIA® plain weave
Wind/Vapour Barrier
- 3.25 oz separate, one way breathable for wind & moisture resistance
Inner Liner
- 3.25 oz Nomex IIIA® inner liner
Nomex IIIA Full Zip Hoodie
GARMENT CONSTRUCTION
- Attached hood w/ 100% cotton draw string
- Two way #5 brass zipper set on Nomex® tape
- Elasticized cuffs
- Adjustable drawstring closure at waist
- Interior storm flap at zipper
- Front pouch pockets
SIZING
- Chest size Small through 4XL, Regular & Tall
- Sizing Chart
STANDARDS MET
- ASTM F 1506 Electric Arc Flash Apparel Standard
- Ebt 24.4 cal/cm2 (Electric Arc Flash Rating)
- HRC 2: CSA Z462 & NFPA 70E (Electrical Workplace Safety Standards)
REFLECTIVE TRIM
- Non applicable
FABRIC
- Inherently flame resistant 13 oz Nomex IIIA® fleece
- ASTM F 1930 (NFPA 2112-Coverall)7%? 2nd & 3rd degree burn
Nomex IIIA 1/4 Zip Hoodie
GARMENT CONSTRUCTION
- Attached hood w/ 100% cotton draw string
- 7 inch YKK brass zipper set on Nomex® tape
- Elasticized cuffs
- Adjustable drawstring closure at waist
- Interior storm flap at zipper
- Front pouch pocket
SIZING
- Chest size Small through 4XL, Regular & Tall
- Sizing Chart
STANDARDS MET
- ASTM F 1506 Electric Arc Flash Apparel Standard
- Ebt 24.4 cal/cm2 (Electric Arc Flash Rating)
- HRC 2: CSA Z462 & NFPA 70E (Electrical Workplace Safety Standards)
REFLECTIVE TRIM
- Non applicable
FABRIC
- Inherently flame resistant 13 oz Nomex IIIA® fleece
- ASTM F 1930 (NFPA 2112-Coverall)7%? 2nd & 3rd degree burn
Hard Hat Liner
OUTER SHELL
- Inherently flame resistant 6 oz Nomex IIIA® plain weave
- ASTM F 1930 (NFPA 2112) 25.41% 2nd & 3rd degree
GARMENT CONSTRUCTION
- 3.25 oz separate, one way breathable wind and vapor barrier
- Quilted flame resistant 14 oz Moda-Quilt® insulation
- Available in 4 hole or 6 hole configurations
- Adjustable chin strap with hook & loop closure
SIZING
- One size
OUTER SHELL
- 9 oz UltraSoft® twill weave
- 88% Flame Resistant Cotton/12% High Tenacity FR Nylon
- ASTM F 1930 (NFPA 2112) 9% 2nd & 3rd degree
GARMENT CONSTRUCTION
- 3.25 oz separate, one way breathable wind and vapor barrier
- Quilted flame resistant 14 oz Moda-Quilt® insulation
- Available in 4 hole configuration
- Adjustable chin strap with hook & loop closure
SIZING
- One size
Nomex IIIA Work Shirt
GARMENT CONSTRUCTION
- Button down collar
- Placket front with button closure
- Double back yoke
- Two patch chest pockets with flap, button closure
- Pencil slot in left pocket
- Adjustable button cuffs
- Hemmed bottom edge
SIZING
- Chest size Small through 4XL, Regular & Tall
- Sizing Chart
STANDARDS MET
- CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
- HRC 1: CSA Z462-08 & NFPA 70E (Electrical Workplace Standards)
- ATPV 5.1 cal/cm2 (Electric Arc Flash Rating)
REFLECTIVE TRIM
- Non applicable
FABRIC
- Inherently flame resistant 6 oz Nomex IIIA® plain weave
- 100% Nomex IIIA®
- ASTM F 1930 (NFPA 2112) 25.41% 2nd & 3rd degree
Nomex IIIA Work Pant
GARMENT CONSTRUCTION
- Button front closure
- #5 zipper set to Nomex® tape
- 7 belt loops
- Two front slash pockets
- Two back patch pockets
- Unfinished bottom hem
- Relaxed fit
SIZING
- Waist size- even sizes 30W through 48W
- Sizing Chart
STANDARDS MET
- CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
- HRC 1: CSA Z462-08 & NFPA 70E (Electrical Workplace Standards)
- ATPV 5.1 cal/cm2 (Electric Arc Flash Rating)
REFLECTIVE TRIM
- Non applicable
FABRIC
- Inherently flame resistant 6 oz Nomex IIIA® plain weave
- 100% Nomex IIIA®
- ASTM F 1930 (NFPA 2112) 25.41% 2nd & 3rd degree
Nomex IIIA Insulated Bomber
GARMENT CONSTRUCTION
- Protective insulated stand-up collar
- Two-way heavy duty #10 brass zipper on Nomex® tape
- Storm guard over zipper with snap closures
- Adjustable snap cuff for warmth and lower arm protection
- Fully elasticized separate waistband
- Reflective tape double stitched
SIZING
- Chest size Small through 4XL, Short, Regular & Tall
- Sizing Chart
STANDARDS MET
- CAN/CGSB-155.20-2000 (Hydrocarbon Flash Fire)
- HRC 1: CSA Z462-08 & NFPA 70E (Electrical Workplace Standards)
REFLECTIVE TRIM
- Reflective WorX FR5020 –– Industrial wash
COMPONENTS
Outer Shell
- Inherently flame resistant 6.0 oz Nomex IIIA® plain weave
Wind/Vapour Barrier
- 3.25 oz separate, one way breathable for wind & moisture resistance
Insulation
- Quilted flame resistant 14 oz Moda-Quilt®
Nomex IIIA Fleece Jacket
GARMENT CONSTRUCTION
- Protective stand-up collar
- Two-way heavy duty #5 brass zipper on Nomex® tape
- Elasticized cuffs
- Adjustable drawstring closure at waist
- Interior storm flap at zipper
- 3 in 1 capability- Outer shell sold separately
SIZING
- Chest size Small through 4XL, Regular & Tall
- Sizing Chart
STANDARDS MET
- ASTM F 1506 Electric Arc Flash Apparel Standard
- Ebt 24.4 cal/cm2 (Electric Arc Flash Rating)
- HRC 2: CSA Z462 & NFPA 70E (Electrical Workplace Safety Standards)
REFLECTIVE TRIM
- Reflective WorX FR5020 –– Industrial wash
FABRIC
- Inherently flame resistant 13 oz Nomex IIIA® fleece
- ASTM F 1930 (NFPA 2112-Coverall)7%? 2nd & 3rd degree burn